Rigol DS1000Z Series Specifications

Browse online or download Specifications for Measuring, testing & control Rigol DS1000Z Series. Rigol DS1000Z Series Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Digital Oscilloscope

RIGOL Quick Guide MSO1000Z/DS1000Z Series Digital Oscilloscope Jul. 2014 RIGOL Technologies, Inc.

Page 2

RIGOL VIII MSO1000Z/DS1000Z Quick Guide Measurement Category Measurement Category MSO1000Z/DS1000Z series digital oscilloscopes can make measureme

Page 3 - Guaranty and Declaration

RIGOL MSO1000Z/DS1000Z Quick Guide IX Working Environment Temperature Operating: 0℃ to +50℃ Non-operating: -40℃ to +70℃ Humidity 0℃ to +30℃: ≤95% re

Page 4 - Safety Requirement

RIGOL X MSO1000Z/DS1000Z Quick Guide Safety Class Class 1 – Grounded Product General Care and Cleaning General Care: Do not store or leave th

Page 5

RIGOL MSO1000Z/DS1000Z Quick Guide XI Document Overview This manual is used to guide users to quickly get familiar with the front panel, rear panel,

Page 6 - Safety Terms and Symbols

RIGOL XII MSO1000Z/DS1000Z Quick Guide Contents Guaranty and Declaration ...

Page 7

RIGOL MSO1000Z/DS1000Z Quick Guide 1 Quick Start General Inspection 1. Inspect the shipping container for damage. Keep the damaged shipping conta

Page 8

RIGOL 2 MSO1000Z/DS1000Z Quick Guide Appearance and Dimensions Figure 1 Front View Unit: mm Figure 2 Top View

Page 9

RIGOL MSO1000Z/DS1000Z Quick Guide 3 To Prepare for Operation To Adjust the Supporting Legs Adjust the supporting legs properly to use them as stand

Page 10 - Ventilation Requirement

RIGOL 4 MSO1000Z/DS1000Z Quick Guide Power-on Inspection When the oscilloscope is energized, press the power key at the lower-left corner of the

Page 11 - Working Environment

RIGOL MSO1000Z/DS1000Z Quick Guide 5 Connect the Logic Probe: 1. Connect the single-wire terminal of the logic probe to Digital Channel Interface at

Page 13 - Document Overview

RIGOL 6 MSO1000Z/DS1000Z Quick Guide Function Inspection 1. Press Storage  Default to restore the oscilloscope to its default configuration. 2.

Page 14 - Contents

RIGOL MSO1000Z/DS1000Z Quick Guide 7 Probe Compensation When the probes are used for the first time, you should compensate the probes to match the in

Page 15 - Quick Start

RIGOL 8 MSO1000Z/DS1000Z Quick Guide Front Panel Overview Figure 10 Front Panel Overview Table 1 Front Panel Description No. Description No

Page 16 - Appearance and Dimensions

RIGOL MSO1000Z/DS1000Z Quick Guide 9 Rear Panel Overview Figure 11 Rear Panel Overview 1. Handle Pull up the handle vertically for easy carryin

Page 17 - To Prepare for Operation

RIGOL 10 MSO1000Z/DS1000Z Quick Guide The instrument can output a positive pulse via this connector when a failed waveform is detected during the p

Page 18 - To Connect the Probe

RIGOL MSO1000Z/DS1000Z Quick Guide 11 Front Panel Function Overview VERTICAL CH1, CH2, CH3, CH4: analog channel setting keys. The 4 channels are ma

Page 19 - User’s Guide

RIGOL 12 MSO1000Z/DS1000Z Quick Guide Logic Analyzer Press this key to open the logic analyzer control menu. You can turn on or off any channel o

Page 20 - Function Inspection

RIGOL MSO1000Z/DS1000Z Quick Guide 13 HORIZONTAL HORIZONTAL POSITION: modify the horizontal position. The trigger point would move left or right

Page 21 - Probe Compensation

RIGOL 14 MSO1000Z/DS1000Z Quick Guide CLEAR Press this key to clear all the waveforms on the screen. If the oscilloscope is in “RUN” state, new w

Page 22 - Overview

RIGOL MSO1000Z/DS1000Z Quick Guide 15 Multifunction Knob Adjust waveform brightness: In non-menu-operation mode, turn this knob to adjust the bright

Page 23 - Rear Panel Overview

RIGOL MSO1000Z/DS1000Z Quick Guide I Guaranty and Declaration Copyright © 2013 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information R

Page 24 - RIGOL

RIGOL 16 MSO1000Z/DS1000Z Quick Guide Display: press this key to enter display setting menu to set the display type, persistence time, wave intensi

Page 25 - VERTICAL

RIGOL MSO1000Z/DS1000Z Quick Guide 17 User Interface MSO1000Z/DS1000Z provides 7.0 inches, WVGA (800*480) 160,000 color TFT LCD. Figure 12 Us

Page 26 - Signal Source

RIGOL 18 MSO1000Z/DS1000Z Quick Guide 3. Status Available states include RUN, STOP, T’D (triggered), WAIT and AUTO. 4. Horizontal Time Base  R

Page 27 - TRIGGER

RIGOL MSO1000Z/DS1000Z Quick Guide 19 level value will change with the up and down of . Note: in slope trigger, runt trigger and windows trigger, th

Page 28 - RUN/STOP

RIGOL 20 MSO1000Z/DS1000Z Quick Guide  When the impedance of signal source is set to 50 Ω, will be displayed at the bottom of the Source1 Wavef

Page 29 - Function Menus

RIGOL MSO1000Z/DS1000Z Quick Guide 21 Parameter Setting Method This oscilloscope provides two methods to set the basic parameters. Method 1: When i

Page 30

RIGOL 22 MSO1000Z/DS1000Z Quick Guide To Use the Built-in Help System The help system of this oscilloscope provides instructions for all the funct

Page 31 - User Interface

RIGOL MSO1000Z/DS1000Z Quick Guide 23 Troubleshooting The commonly encountered failures and their solutions are listed below. When you encounter thos

Page 32

RIGOL 24 MSO1000Z/DS1000Z Quick Guide 6. The display of waveform is ladder-like: (1) The horizontal time base might be too low. Increase the hori

Page 33 - MSO1000Z/DS1000Z Quick Guide

RIGOL II MSO1000Z/DS1000Z Quick Guide Safety Requirement General Safety Summary Please review the following safety precautions carefully before p

Page 34

RIGOL MSO1000Z/DS1000Z Quick Guide III Do Not Operate in Wet Conditions. In order to avoid short circuiting to the interior of the device or electric

Page 35 - To Use the Security Lock

RIGOL IV MSO1000Z/DS1000Z Quick Guide Safety Terms and Symbols Terms Used in this Manual. These terms may appear in this manual: WARNING Warni

Page 36

RIGOL MSO1000Z/DS1000Z Quick Guide V Allgemeine Sicherheits Informationen Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonenschäden

Page 37 - Troubleshooting

RIGOL VI MSO1000Z/DS1000Z Quick Guide Nicht in feuchter Umgebung betreiben. Zur Vermeidung von Kurzschluß im Geräteinneren und Stromschlag betreibe

Page 38

RIGOL MSO1000Z/DS1000Z Quick Guide VII Sicherheits Begriffe und Symbole Begriffe in diesem Guide. Diese Begriffe können in diesem Handbuch auftauchen