DM3058 5½ Digital Multimeter
Features and Benets
Measurement Function
DC Voltage
DC Current
AC Voltage (RMS)
AC Current (RMS)
Frequency Range/Test Current
20 Hz ~ 100 kHz
20 Hz ~ 10 kHz
Range
200 mV ~ 1000 V
200 μA ~ 10 A
200 mV ~ 750 V
20 mA ~ 10 A
Accuracy: 1 Year ± (%of reading +%of range)
0.015 + 0.003
0.055+0.005
0.20 + 0.05
0.30+0.10
Specications
Resistance
(2-wire and 4-wire)
Capacitance
Diode
Continuity
Frequency and Period
200 Ω ~ 100 MΩ
2 nF ~ 10000 uF
2.4 V
2 kΩ
200 mV ~ 750 V
1 mA
1 mA
20 Hz ~ 1 MHz
0.020 + 0.003
1 + 0.5
0.05 + 0.01
0.05 + 0.01
0.01+0.003
Note: All the indicators are the typical value under standard test situation
Measurement Function
Math
Other Functions
Display Characteristic
Safety
Shock and Vibration
Power Supply
DC Voltage, DC Current, AC Voltage (RMS), AC Current (RMS), Resistance (2-wire and 4-wire), Capacitance,
Diodes, Frequency and Period, Continuity, Short Current, Any Sensor
“Pass/Fail” Limit Test, Standard Deviation, Histogram, Relatively, Null, Max/Min/Avg, dBm, dB
Built-in 10 groups of conguration storage,10 groups of conguration storage of any sensor, 2048 historical
reading data record and check, 10 groups of historical datum storage, Exterior trigger input and VMC output,
Reading hold, Single trigger
Multi-display, Menu, Multi-language help and Waveform display
CAT I 1000 V/CAT II 600 V, Pollution level 2
MIL-T-28800E, type III, class 5 (sine)
AC 100 V ~ 120 V 45 Hz ~ 440 Hz
AC 200 V ~ 240 V 45 Hz ~ 66 Hz
20 VA peak value
Other Parameters
Other Features
Pass / Fail Multi-Display
UltraSensor Software for any types of electrical sensor measurements
Ultrasensor Software Interface
Real 5 ½ digits readings resolution
Up to 123 rdgs/s of measurement speed
True-RMS AC Voltage Current measuring
Quickly Save or Recall the 10 groups of Preset Conguration
Preset 10 groups of Standard Sensor Conguration, built-in Thermocouple
compensate in Cold Terminal
Clone or backup all the congurations within instrument into other DM3058 via U-disc
With easy, convenient and exible random sensor measurement control software:
UltraSensor
Standard conguration interface: USB Device, USB Host, LAN, RS-232, GPIB,
and support U-disc storage and Web remote control