RIGOL Quick Guide DSA1000 Series Spectrum Analyzer Apr. 2015 RIGOL Technologies, Inc
RIGOL VIII Quick Guide for DSA1000 Series Sorgen Sie für eine elektrostatisch geschützte Umgebung, um somit Schäden und Funktionsstörungen durch ESD
RIGOL Quick Guide for DSA1000 Series IX Sicherheits Begriffe und Symbole Begriffe in diesem Guide. Diese Begriffe können in diesem Handbuch auftauch
RIGOL X Quick Guide for DSA1000 Series General Care and Cleaning General Care Do not store or leave the instrument in where the instrument will be
RIGOL Quick Guide for DSA1000 Series XI Environmental Considerations The following symbol indicates that this product complies with the WEEE Directiv
RIGOL Contents XII Quick Guide for DSA1000 Series Contents Front Panel ...
RIGOL Quick Guide for DSA1000 Series 1 Front Panel Figure 1 Front panel overview Table 1 Front Panel Description No. Description No. Descripti
RIGOL 2 Quick Guide for DSA1000 Series Front Panel Function Key Figure 2 Function key area Table 2 Function keys description Keys Descripti
RIGOL Quick Guide for DSA1000 Series 3 Function keys description (Continued) Keys Description Searches signals automatically within full frequency
RIGOL 4 Quick Guide for DSA1000 Series Function keys description (Continued) Keys Description Special function such as noise marker, N dB bandwid
RIGOL Quick Guide for DSA1000 Series 5 Front Panel Backlight Key The backlight status of some keys at the front panel, off, bright or different color
RIGOL 6 Quick Guide for DSA1000 Series 6. Battery status indicator (China Only) It is used to indicate the installation status and the current a
RIGOL Quick Guide for DSA1000 Series 7 Front Panel Connector Figure 3 Front Panel Connectors 1. USB Host The analyzer may serve as a “host” device
RIGOL 8 Quick Guide for DSA1000 Series Figure 5 Tracking generator output connection CAUTION Reverse power or voltage mustn’t be higher than 1
RIGOL Quick Guide for DSA1000 Series 9 CAUTION To avoid damages to the instrument, signals at the input terminal must be less than 50 V DC voltag
RIGOL 10 Quick Guide for DSA1000 Series Rear Panel Figure 7 Rear panel overview 1. AC power connector Available AC power supply types: AC:
RIGOL Quick Guide for DSA1000 Series 11 Figure 8 TRIGGER IN connection 4. 10 MHz IN/OUT The BNC input or output of the 10 MHz reference clock, see
RIGOL 12 Quick Guide for DSA1000 Series Figure 10 VGA port connection 6. USB Device Interface This configurable USB port permits interface exter
RIGOL Quick Guide for DSA1000 Series 13 7. LAN interface Through this interface, the analyzer can be connected to your local network for remote contr
RIGOL 14 Quick Guide for DSA1000 Series Prepare for Use General Inspection Please inspect your new analyzer according to the following steps: 1.
RIGOL Quick Guide for DSA1000 Series 15 A power cord that meets the A USB Cable standard of destination country A
RIGOL Quick Guide for DSA1000 Series I Guaranty and Declaration Copyright © 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Informatio
RIGOL 16 Quick Guide for DSA1000 Series Disassemble the Front Panel Cover Before putting your analyzer into action, remove the front panel cover
RIGOL Quick Guide for DSA1000 Series 17 Connect the AC Power Please use the power cord provided for AC powering, see figure below. For the AC voltag
RIGOL 18 Quick Guide for DSA1000 Series Use the Battery (China Only) The spectrum analyzer provides optional rechargeable battery. Please install
RIGOL Quick Guide for DSA1000 Series 19 Power-on Check Turn on the power switch at the rear panel, then press down the power button on the front pan
RIGOL 20 Quick Guide for DSA1000 Series Replace Fuse Please replace with specified fuse according to the following steps when needed: 1. Turn of
RIGOL Quick Guide for DSA1000 Series 21 Charge the Battery (China Only) Please install the battery by referring to the introduction in “Use the Batte
RIGOL 22 Quick Guide for DSA1000 Series User Interface 1 2 3 4 5 6 7 8 9 1011 1213 14 15 16 17 1831 30 29 28 27 26 232425 2219 20213233343536373841
RIGOL Quick Guide for DSA1000 Series 23 Table 3 User interface legends NO. Name Explanation 1 LOGO Logo of RIGOL 2 System status (“UNCAL” and “
RIGOL 24 Quick Guide for DSA1000 Series User interface legends (Continued) NO. Name Explanation 12 Menu item Menu item of current function. 13
RIGOL Quick Guide for DSA1000 Series 25 User interface legends (Continued) NO. Name Explanation 29 RBW Resolution bandwidth of frequency. 30 C
RIGOL II Quick Guide for DSA1000 Series General Safety Summary Please review the following safety precautions carefully before putting the instrumen
RIGOL 26 Quick Guide for DSA1000 Series User interface legends (Continued) NO. Name Explanation 41 Trace 3 types and status Trace types: Clear
RIGOL Quick Guide for DSA1000 Series 27 Menu Operation There are 7 different menus with respect to different modes of operation: 1. Parameter Input
RIGOL 28 Quick Guide for DSA1000 Series 5. Direct Execution 6. Function Switch + Parameter Input 7. Selected State Execute the fu
RIGOL Quick Guide for DSA1000 Series 29 Parameter Input In this part, you will learn how to enter desired parameter values from the numerical keyboar
RIGOL 30 Quick Guide for DSA1000 Series 5. Enter When pressed, the system will complete the input process and insert a default measuring unit for
RIGOL Quick Guide for DSA1000 Series 31 Knob Figure 22 The knob The knob has following functions: 1. During parameter editing, turn the knob clockw
RIGOL 32 Quick Guide for DSA1000 Series Basic Measurement In this section, we introduce how to use the analyzer to do basic measurements. Consideri
RIGOL Quick Guide for DSA1000 Series 33 5. Setup Span (1) Press SPAN, a corresponding menu will appear on the screen, and Span is in high-bright stat
RIGOL 34 Quick Guide for DSA1000 Series Figure 24 Measuring results
RIGOL Quick Guide for DSA1000 Series 35 On-line Help System The built-in help provides information refers to every function key and menu key on the
RIGOL Quick Guide for DSA1000 Series III components when the unit is powered. Do Not Operate With Suspected Failures. If you suspect damage occurs
RIGOL 36 Quick Guide for DSA1000 Series Figure 25 On-line help
RIGOL Quick Guide for DSA1000 Series 37 Troubleshooting To help you solve commonly encountered problems we have listed some typical issues with their
RIGOL 38 Quick Guide for DSA1000 Series and contact RIGOL. 3. The spectrum lines on the screen do not update for long periods: (1) Check if the sc
RIGOL Quick Guide for DSA1000 Series 39 5. Prompt Message: The instrument may give common prompts, error prompts, or state prompts according to the
RIGOL IV Quick Guide for DSA1000 Series voltage components and 30 dBm (1W) AC (RF) components. Appropriate Use of Power Meter. If you are not sure of
RIGOL Quick Guide for DSA1000 Series V Safety Terms and Symbols Terms Used in this Manual. These terms may appear in this manual: WARNING Warnin
RIGOL VI Quick Guide for DSA1000 Series Allgemeine Sicherheits Informationen Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonensch
RIGOL Quick Guide for DSA1000 Series VII geöffnet. Der Betrieb mit offenen oder entfernten Gehäuseteilen ist nicht zulässig. Nichts in entsprechende
Comments to this Manuals