Rigol DSA1030 User Manual

Browse online or download User Manual for Measuring instruments Rigol DSA1030. RIGOL DSA1030 User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - DSA1000 Series

RIGOL Quick Guide DSA1000 Series Spectrum Analyzer Apr. 2015 RIGOL Technologies, Inc

Page 2

RIGOL VIII Quick Guide for DSA1000 Series Sorgen Sie für eine elektrostatisch geschützte Umgebung, um somit Schäden und Funktionsstörungen durch ESD

Page 3 - Guaranty and Declaration

RIGOL Quick Guide for DSA1000 Series IX Sicherheits Begriffe und Symbole Begriffe in diesem Guide. Diese Begriffe können in diesem Handbuch auftauch

Page 4 - General Safety Summary

RIGOL X Quick Guide for DSA1000 Series General Care and Cleaning General Care Do not store or leave the instrument in where the instrument will be

Page 5

RIGOL Quick Guide for DSA1000 Series XI Environmental Considerations The following symbol indicates that this product complies with the WEEE Directiv

Page 6

RIGOL Contents XII Quick Guide for DSA1000 Series Contents Front Panel ...

Page 7 - Safety Terms and Symbols

RIGOL Quick Guide for DSA1000 Series 1 Front Panel Figure 1 Front panel overview Table 1 Front Panel Description No. Description No. Descripti

Page 8

RIGOL 2 Quick Guide for DSA1000 Series Front Panel Function Key Figure 2 Function key area Table 2 Function keys description Keys Descripti

Page 9

RIGOL Quick Guide for DSA1000 Series 3 Function keys description (Continued) Keys Description Searches signals automatically within full frequency

Page 10

RIGOL 4 Quick Guide for DSA1000 Series Function keys description (Continued) Keys Description Special function such as noise marker, N dB bandwid

Page 11

RIGOL Quick Guide for DSA1000 Series 5 Front Panel Backlight Key The backlight status of some keys at the front panel, off, bright or different color

Page 13 - Environmental Considerations

RIGOL 6 Quick Guide for DSA1000 Series 6. Battery status indicator (China Only) It is used to indicate the installation status and the current a

Page 14 - Contents

RIGOL Quick Guide for DSA1000 Series 7 Front Panel Connector Figure 3 Front Panel Connectors 1. USB Host The analyzer may serve as a “host” device

Page 15 - Front Panel

RIGOL 8 Quick Guide for DSA1000 Series Figure 5 Tracking generator output connection CAUTION Reverse power or voltage mustn’t be higher than 1

Page 16 - Front Panel Function Key

RIGOL Quick Guide for DSA1000 Series 9 CAUTION To avoid damages to the instrument, signals at the input terminal must be less than 50 V DC voltag

Page 17

RIGOL 10 Quick Guide for DSA1000 Series Rear Panel Figure 7 Rear panel overview 1. AC power connector Available AC power supply types: AC:

Page 18

RIGOL Quick Guide for DSA1000 Series 11 Figure 8 TRIGGER IN connection 4. 10 MHz IN/OUT The BNC input or output of the 10 MHz reference clock, see

Page 19 - Front Panel Backlight Key

RIGOL 12 Quick Guide for DSA1000 Series Figure 10 VGA port connection 6. USB Device Interface This configurable USB port permits interface exter

Page 20

RIGOL Quick Guide for DSA1000 Series 13 7. LAN interface Through this interface, the analyzer can be connected to your local network for remote contr

Page 21 - Front Panel Connector

RIGOL 14 Quick Guide for DSA1000 Series Prepare for Use General Inspection Please inspect your new analyzer according to the following steps: 1.

Page 22

RIGOL Quick Guide for DSA1000 Series 15 A power cord that meets the A USB Cable standard of destination country A

Page 23

RIGOL Quick Guide for DSA1000 Series I Guaranty and Declaration Copyright © 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Informatio

Page 24 - Rear Panel

RIGOL 16 Quick Guide for DSA1000 Series Disassemble the Front Panel Cover Before putting your analyzer into action, remove the front panel cover

Page 25

RIGOL Quick Guide for DSA1000 Series 17 Connect the AC Power Please use the power cord provided for AC powering, see figure below. For the AC voltag

Page 26

RIGOL 18 Quick Guide for DSA1000 Series Use the Battery (China Only) The spectrum analyzer provides optional rechargeable battery. Please install

Page 27

RIGOL Quick Guide for DSA1000 Series 19 Power-on Check Turn on the power switch at the rear panel, then press down the power button on the front pan

Page 28 - Prepare for Use

RIGOL 20 Quick Guide for DSA1000 Series Replace Fuse Please replace with specified fuse according to the following steps when needed: 1. Turn of

Page 29 - User’s Guide

RIGOL Quick Guide for DSA1000 Series 21 Charge the Battery (China Only) Please install the battery by referring to the introduction in “Use the Batte

Page 30 - Connect the Power

RIGOL 22 Quick Guide for DSA1000 Series User Interface 1 2 3 4 5 6 7 8 9 1011 1213 14 15 16 17 1831 30 29 28 27 26 232425 2219 20213233343536373841

Page 31 - Connect the AC Power

RIGOL Quick Guide for DSA1000 Series 23 Table 3 User interface legends NO. Name Explanation 1 LOGO Logo of RIGOL 2 System status (“UNCAL” and “

Page 32 - Use the Battery (China Only)

RIGOL 24 Quick Guide for DSA1000 Series User interface legends (Continued) NO. Name Explanation 12 Menu item Menu item of current function. 13

Page 33 - Use the Lock

RIGOL Quick Guide for DSA1000 Series 25 User interface legends (Continued) NO. Name Explanation 29 RBW Resolution bandwidth of frequency. 30 C

Page 34 - Replace Fuse

RIGOL II Quick Guide for DSA1000 Series General Safety Summary Please review the following safety precautions carefully before putting the instrumen

Page 35

RIGOL 26 Quick Guide for DSA1000 Series User interface legends (Continued) NO. Name Explanation 41 Trace 3 types and status Trace types: Clear

Page 36 - User Interface

RIGOL Quick Guide for DSA1000 Series 27 Menu Operation There are 7 different menus with respect to different modes of operation: 1. Parameter Input

Page 37

RIGOL 28 Quick Guide for DSA1000 Series 5. Direct Execution 6. Function Switch + Parameter Input 7. Selected State Execute the fu

Page 38

RIGOL Quick Guide for DSA1000 Series 29 Parameter Input In this part, you will learn how to enter desired parameter values from the numerical keyboar

Page 39

RIGOL 30 Quick Guide for DSA1000 Series 5. Enter When pressed, the system will complete the input process and insert a default measuring unit for

Page 40

RIGOL Quick Guide for DSA1000 Series 31 Knob Figure 22 The knob The knob has following functions: 1. During parameter editing, turn the knob clockw

Page 41 - Menu Operation

RIGOL 32 Quick Guide for DSA1000 Series Basic Measurement In this section, we introduce how to use the analyzer to do basic measurements. Consideri

Page 42

RIGOL Quick Guide for DSA1000 Series 33 5. Setup Span (1) Press SPAN, a corresponding menu will appear on the screen, and Span is in high-bright stat

Page 43 - Parameter Input

RIGOL 34 Quick Guide for DSA1000 Series Figure 24 Measuring results

Page 44

RIGOL Quick Guide for DSA1000 Series 35 On-line Help System The built-in help provides information refers to every function key and menu key on the

Page 45 - Directional Keys

RIGOL Quick Guide for DSA1000 Series III components when the unit is powered. Do Not Operate With Suspected Failures. If you suspect damage occurs

Page 46 - Basic Measurement

RIGOL 36 Quick Guide for DSA1000 Series Figure 25 On-line help

Page 47

RIGOL Quick Guide for DSA1000 Series 37 Troubleshooting To help you solve commonly encountered problems we have listed some typical issues with their

Page 48

RIGOL 38 Quick Guide for DSA1000 Series and contact RIGOL. 3. The spectrum lines on the screen do not update for long periods: (1) Check if the sc

Page 49 - On-line Help System

RIGOL Quick Guide for DSA1000 Series 39 5. Prompt Message: The instrument may give common prompts, error prompts, or state prompts according to the

Page 50

RIGOL IV Quick Guide for DSA1000 Series voltage components and 30 dBm (1W) AC (RF) components. Appropriate Use of Power Meter. If you are not sure of

Page 51 - Troubleshooting

RIGOL Quick Guide for DSA1000 Series V Safety Terms and Symbols Terms Used in this Manual. These terms may appear in this manual: WARNING Warnin

Page 52

RIGOL VI Quick Guide for DSA1000 Series Allgemeine Sicherheits Informationen Überprüfen Sie diefolgenden Sicherheitshinweise sorgfältigumPersonensch

Page 53

RIGOL Quick Guide for DSA1000 Series VII geöffnet. Der Betrieb mit offenen oder entfernten Gehäuseteilen ist nicht zulässig. Nichts in entsprechende

Comments to this Manuals

No comments