RIGOL Chapter 2 Command System
2-64 DS1000Z Programming Guide
:REFerence<n>:VOFFset
Syntax :REFerence<n>:VOFFset <offset>
:REFerence<n>:VOFFset?
Description Set or query the vertical offset of the specified reference channel. The unit is the same
as the unit of the source.
Parameter
Name
Type
Range
Default
<n>
Discrete
{1|2|3|4|5|6|7|8|9|10}
None
<offset>
Real
-10*RefVerticalScale to 10*RefVerticalScale
0
Explanation
RefVerticalScale refers to the vertical scale of the reference channel.
Return Format
The query returns the vertical offset in scientific notation.
Example
:REFerence1:VOFFset 10
Related
Command
:REFerence<n>:SOURce
:REFerence<n>:VSCale
:REFerence<n>:RESet
Syntax
:REFerence<n>:RESet
Description
Reset the vertical scale and vertical offset to its default values.
Parameter
Name
Type
Range
Default
<n>
Discrete
{1|2|3|4|5|6|7|8|9|10}
Page view 77