Rigol DSG3000 Series Specifications Page 136

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 135
RIGOL
DS6000 Users Guide
6-16
Time Parameters
1. Period: defined as the time between the two crossing points of the middle
threshold values of two continuous edges with the same polarity.
2. Frequency: defined as the reciprocal of period.
3. Rise Time: the time that the signal amplitude rises from 10% to 90%.
4. Fall Time: the time that the signal amplitude falls from 90% to 10%.
5. + Width: the time from the 50% threshold of a rising edge to the 50%
threshold of the next falling edge.
6. - Width: the time from the 50% threshold of a falling edge to the 50%
threshold of the next rising edge.
7. + Duty: the ratio of the positive pulse width to the period.
8. - Duty: the ratio of the negative pulse width to the period.
RiseTime
FallTime
90%
50%
10%
+Width
-Width
Page view 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 261 262

Comments to this Manuals