Programming Overview RIGOL
Programming Guide for DG1000
1-5
Parameter Type
The commands contain 5 kinds of parameters, different parameters have different
setting methods.
1. Boolean Parameters
The parameters could be OFForON” (“0” or “1”), for example,
AM:STATE {OFF|ON}
OFFdenotes disabling AM function. Ondenotes enabling AM function.
2. Consecutive Integer Parameters
The parameters could be a consecutive integer, for example,
DISPlay:CONTRAST <value>
<value> could be any integer between 0 and 31(including 0 and 31).
3. Consecutive Real Number Parameters
The parameters could be any value within the effective range and with the
required precision, for example,
FREQuency {<frequency>|MINimum|MAXimum}
For sine wave, <frequency> could be any real number between 1uHz and 20MHz.
4. Discrete Parameters
The parameters could be a cited value, for example,
MEMory:STATe:NAME? {0|1|2|3|4|5|6|7|8|9|10}
The parameter could only be 0, 1, 2, 3, 4, 5, 6. 7, 8, 9 or 10.
5. ASCII Character String
The parameters should be the combinations of ASCII characters, for example,
DATA:COPY <destination arb name>[,VOLATILE]
<destination arb name> is a character string defined by user.
Page view 10