RIGOL DG1000 Command System
Programming Guide for DG1000
2-8
CH2.
Explanations Although the frequency and amplitude parameters make no
impression on this command, a value or “DEFault” must be
specified.
If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude> and <offset>
are Hz, Vpp and V
DC
respectively.
Example APPL:DC:CH2 DEF,DEF,1.5
15.
APPLy:USER:CH2
Syntax APPLy:USER:CH2 [<frequency>[,<amplitude>[,<offset>]]]
Function Generate an arbitrary wave (with specific
DC offset) selected by the FUNCtion:USER:CH2 command via CH2.
Explanations If the parameters you set are less than three, the sequence
would be: <frequency>, <amplitude>, <offset>.
The default units of <frequency>, <amplitude> and <offset>
are Hz, Vpp and V
DC
respectively.
Example APPL:USER:CH2 1000,5.0,-1.5
16.
APPLy:CH2?
Syntax APPLy:CH2?
Function Query the current configuration
of CH2 and the type of wave
outputted.
Return Value The query returns a character string enclosed in double quotation
marks, including function, frequency, amplitude and offset. Such as,
CH2:"SIN,1.000000e+03,5.000000e+00,-1.500000e+00".