Rigol DS1204B Specifications Page 126

  • Download
  • Add to my manuals
  • Print
  • Page
    / 152
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 125
RIGOL Command Systems
Programming Guide for DS1000B Series
2-114
Returned Format:
The query returns Channel1 or Channel2, Channel3, Channel4, Math, None.
Example:
:CURS:TRAC:SOURB CHAN1 Set the signal source B of track cursor.
:CURS:TRAC:SOURB? Return Channel1.
10. :CURSor:TRACk:CURA
Command Format:
:CURSor:TRACk:CURA <value>
:CURSor:TRACk:CURA?
Function:
The command sets the position of track cursor A. The <value> range is 4~297.
Returned Format:
The query returns the position of cursor A.
Example:
:CURS:TRAC:CURA 100 Set the position of track cursor A as 100.
:CURS:TRAC:CURA? Return 100.
11. :CURSor:TRACk:CURB
Command Format:
:CURSor:TRACk:CURB <value>
:CURSor:TRACk:CURB?
Function:
The command sets the position of track cursor B. The <value> range is 4~297.
Returned Format:
The query returns the position of cursor B.
Example:
:CURS:TRAC:CURB 100 Set the position of track cursor B as 100.
Page view 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 151 152

Comments to this Manuals

No comments