RIGOL User’s Guide DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator Jun. 2014 RIGOL Technologies, Inc.
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-2 Output from Single Channel Example 1: Out
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-3 Example 2: Output a
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-4 Example 3: Output a Ramp Waveform How to g
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-5 Example 4: Output a
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-6 Example 5: Output a Noise Waveform How to
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-7 Example 6: Output a
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-8 Example 7: Create an Arbitrary Waveform Ho
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-9 6. Edit the Wavef
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-10 Example 8: To Generate a AM Waveform Ho
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-11 After finishing t
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-1 Chapter 1 Quick Star
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-12 Example 9: To Generate a FSK Waveform H
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-13 Example 10: To Gen
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-14 Instructions If necessary, you can set
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-15 Example 11: To Gen
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-16 Output from Double Channels Output the
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-17 Figure 3-15 Outp
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-18 Figure 3-17 Output Signals with 90° Pha
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-19 Example for Chann
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-20 Figure 3-20 Channel Coupling Interface
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-21 Example for Chann
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-2 General Inspection When you get a new DG1
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-22 To Measure with the Counter Use the Co
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-23 (2) Press Period
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-1 Chapter 4 Prompt
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-2 Prompting Messages Common Messages 1. Nee
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-3 The PRI of Period i
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-4 Error Messages 1. Sorry, unable to N-Cycl
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-5 Data Overflow 1. F
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-6 4. Period lower limit=*** Different wave
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-7 the same mode if th
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-3 Handle Adjustment To
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-8 specified initial point is less than 2, th
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-9 automatically. 32.
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-10 In external PM, the Phase deviation upper
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-11 52. Set Center Fre
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-12 In the Gated mode, the Phase lower negati
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-13 In the infinite mo
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-14 83. The smallest light level is 0! The sm
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 4-15 Troubleshooting 1
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-1 Chapter 5
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-4 The Front/Rear Panel When you get a new
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-2 Characteristics Frequency Waveforms Sine,
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-3 3MHz(not co
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-4 Amplitude Accuracy (1kHz Sine) [1] ±(2% o
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-5 Phase Devia
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-6 Trigger Output Level TTL-compatible into
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-7 Trigger lev
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 5-8 General Specifications Display Type Black
RIGOL © 2008 RIGOL Technologies, Inc.
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 6-2 Appendix B: Warranty RIGOL Technologies, Inc. warrants its products’ mainframe a
RIGOL © 2008 RIGOL Technologies, Inc.
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-5 Rear Panel at a Glanc
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-6 User Interface The Generator provides thr
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-7 To Set a Waveform At
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-8 Figure 1-10 Square Signal in the Menu Dis
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-9 5. Press the Noise b
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-10 To Set the Output As shown in Figure 1
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-11 To Set Modulate/Swe
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-12 Figure 1-19 Sweep Waveform Signal in th
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-13 To Use Digital Inpu
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 1-14 To Use Store/Utility/Help Function As sh
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-1 Chapter 2 Operating Your Generator By now you have got a brief understanding
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-2 To Set Basic Waveforms To Set Sine Wavef
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-3 To Set the Output Frequency/Period 1. Press Sine Freq/Period Freq, to se
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-4 To Set the Output Amplitude 1. Press Sin
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-5 To Set the Offset 1. Press Sine Offset/LoLev Offset, to set the offset. T
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 I Guaranty and Declaration C
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-6 To Set the Initial Phase 1. Press Sine
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-7 To Set Square Waveform Press the Square button, in the Normal Mode, the operat
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-8 Term Explanation: Duty Cycle: The per
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-9 To Set the Duty Cycle 1. Press Square DtyCyc, to set the Duty Cycle. The D
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-10 To Set Ramp Waveform Press the Ramp butt
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-11 To Set the Symmetry 1. Press Ramp Symm, to set the Symmetry. The Symmetry
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-12 To Set Pulse Waveform Press the Pulse bu
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-13 To Set the Pulse Width 1. Press Pulse Width, to set the Pulse Width. The Pu
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-14 To Set the Pulse Delay 1. Press Pulse
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-15 To Set Noise Waveform Press the Noise button, in the Normal Mode, the operati
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 II Safety Notices Review the following safety
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-16 To Set Arbitrary Waveforms Press the Arb
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-17 To Select Arbitrary Waveform There are 48 built-in Arbitrary Waveforms and 10
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-18 To Select the Built-in Waveform Press Arb
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-19 To Select the Stored Waveform Press Arb Load Stored, and enter the followi
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-20 To Edit Arbitrary Waveform The Generator
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-21 To Create a New Waveform Press Arb Edit Create, to set the overall paramet
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-22 1. To Set the Point Number Press Poi
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-23 Figure 2-29 To Set the voltage Figure 2-30 To Edit the Second Point Ta
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-24 4. Save the Waveform to the Non-Volatil
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-25 To Edit the Stored Waveform Press Arb Edit Stored, enter the following in
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 III Safety Terms and Symbols
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-26 To Set Modulated Waveforms Use the Mod b
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-27 To Set AM Waveform The modulated waveform consists of two parts: the Carrier W
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-28 In the Graph Mode, the waveform is shown
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-29 To Set FM Waveform The modulated waveform consists of two parts: the Carrier
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-30 In the Graph Mode, the waveform is shown
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-31 To Set FSK Waveform The FSK Modulation is a modulation method, the output fr
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-32 Table 2-15 Setting the FSK parameters Me
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-33 To Set PM Waveform The modulated waveform consists of two parts: the Carrier
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-34 Press View, in the Graph Mode, the wavef
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-35 To Generate Sweep Signal In the frequency sweep mode, the function generator
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 IV Instrument at a Glance RIGOL DG1000 serie
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-36 Sweep Frequency Setting Use Start and S
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-37 To Generate Burst Signal Burst Function can generate versatile waveforms in b
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-38 Set the N-Cycle Burst Press Burst NCyc
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-39 1. N-Cycle/ Gated N-Cycle has specific number of waveform cycles, and every
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-40 Set the Gated Burst Press Burst Gated,
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-41 To Store and Recall Press the Store/Recall Button, and the operation menu wil
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-42 To Save the Instrument State Users are al
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-43 To Save Data Users are allowed to store data document in any of the 10 Non-Vol
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-44 To Use USB storage As shown in Figure 2-
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-45 To Save a File Press Store/Recall Store, enter the following interface. Ente
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 V Standard interfaces: USB
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-46 1. English Input The English Input In
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-47 2. Chinese Input The Chinese Input Interface is shown in the following fig
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-48 To Set the Utility Function With the Uti
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-49 Press the Utility button, enter the following interface (two pages): Figure
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-50 To Set the Sync Output The Generator prov
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-51 Waveform has a relative starting phase, it may be not intersection). For an in
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-52 Basic Setting of the Two Channels The fol
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-53 1. To Set the Output Load For the [Output] Connector on the Front panel, the
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-54 2. To Set the Inverse Waveform Press Ut
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-55 Channel Coupling Settings Press Utility Coupling, enter the following interf
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 VI Contents Safety Notices ...
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-56 (2) Only frequency or phase can be coup
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-57 To Set the Counter The counter can automatically detect signal with amplitude
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-58 Instructions The data shown on the
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-59 Auto Measurement Setting Press Utility Count Auto, the instrument will se
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-60 3. To Set the Trig Level The trig level
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-61 4. To Set the High Frequency Restrain On/Off High frequency restrain is used
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-62 System Settings Press Utility Syste
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-63 Key points: Power On The Setting is used when the machine is power on.
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-64 1. Language Setting DG1000 series Genera
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-65 3. Set the Format Press Utility System Format, enter the following interf
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 VII System Settings ...
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-66 (3) “ ” as decimal, press Separat. On
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-67 4. To Return to Default Setting Press Utility Setting Default Yes. R
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-68 Period 10ms Delay 0s Phase 0° State
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-69 I/O Settings Press Utility I/O, to view the USB parameters. Figure 2-7
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-70 Test/Cal Settings Press Utility Test
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-71 2. Info The information includes: Model Number, Serial Number and Software V
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-72 Power Amplifier Settings PA1011 power amp
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-73 To Use the Help System You can get a particular help for every button on the
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 2-74 1. View the last message display View
RIGOL © 2008 RIGOL Technologies, Inc. User’s Guide for DG1000 3-1 Chapter 3 Examples
Comments to this Manuals