User’s Guide for DG1000 Series
2-13
To Set the Pulse Width
(1) Press Pulse Æ Width, to set the Pulse Width.
The Pulse Width shown on the screen is the default value when the instrument is
powered or the set value beforehand. When changing the function, if the current
value is valid for the new waveform, it will be used sequentially.
(2) Input the desired Pulse Width
Use the keypad or the knob to input the desired value, choose the unit, and press the
corresponding button. The Generator will change the waveform immediately.
Figure 2-19 Setting the Pulse Width
In the Graph Mode, the waveform is shown in Figure 2-20.
Figure 2-20 Waveform parameters in the Graph mode
Note: Pulse width and Duty cycle are equivalent, once a parameter is changed, the
other one will change accordingly. For instance, the current period is1ms, the pulse
width is 500µs and the duty cycle is 50, when setting the pulse width to be 200µs,
the duty cycle will become 20.
Current Parameter:
Pulse Width